Page view 55
#


Menu Administration/Communications/Serial/PS Protocol
Purpose Sets the binary communications protocol (BCP) for communicating over a
serial interface to a PostScript printer.
Choices Normal—Enables standard, ASCII (7-bit) hex protocol. Data is sent and
received in ASCII format. This mode is recommended if you do not
print binary data. It was designed for data in the printable ASCII
range. Print jobs can change this setting through PostScript
operators.
Normal Fixed—Enables standard, ASCII (7-bit) hex protocol. Print jobs
cannot change this setting through PostScript operators.
Binary—Enables binary communications protocol (BCP). Print jobs can
change this setting through PostScript operators. Data in the printable
ASCII range also prints.
Binary Fixed—Enables binary fixed communications protocol (BCP). Print
jobs cannot alter change this setting through PostScript operators.
Data in the printable ASCII range also prints.
Default Normal
Notes See chapter 3, “Additional Technical Information,” for a full discussion of
PS Protocol.